Product Features:
1. 176-305VAC wide input voltage range
2. Constant Voltage Drive Mode
3. Built in active PF function, PF>0,95
4. High working efficiency up to 90%
5. THD<15%, Flicker-Free Design
6.IP67 waterproof level with fine aluminum housing, suitable for outdoor applications
7. Class 2 Power unit
8. 4KV + 6KV Surge protection, more safety
9. 5 years warranty
Input Parameters:
Items
Specs
Unit
Conditions
Rated Output voltage
24
VDC
Rated Output Current
2.5
A
Rated Output Power
60
W
Tcase
90
℃
Ta:60℃, 230VAC, full load
Efficiency
≥87.5 (Typical 88)
%
240VAC input, Rated Load
Line Regulation
±0.5%
Load Regulation
±1.5%
Voltage tolerance
±3%
Ripple & Noise (max)
≤2.4
Vp-p
Measured at 20MHZ of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor
Rise time
≤60
mS
25℃ , full load
Power On Delay time
≤2
S
200-240VAC, full load
Switch off Hold Up time
/
ms
Rated input voltage, rated load
Input Parameters:
Items
Specs
Unit
Conditions
Rated Input voltage
200-277
VAC
Input voltage range
176-305
VAC
Input Frequency
47-63(Typical 50/60)
Hz
Input Current Max
0.5
A
Vin=176Vac, Full Load
Inrush Current
≤20
A
220Vac, full load, 25℃
Power Factor
≥0.95
176~277Vac input, full load
THD
≤15
%
Vin=176~277Vac, full load
Protection:
Current Limiting
110%-160%
A
Hi-CCUP Mode, Auto-recovery
after fault condition is removed
Short circuit
Yes
Hi-CCUP Mode, Auto-recovery
after fault condition is removed
Input Undervoltage protection
>80
V
Temperature Condition:
Operating Temperature range
-40 to +80(Typical25)
℃
Refer to Derating Curve
Storage Temperature range
-45 to +80(Typical25
℃
Humidity
10~95
%
NON-Condensing
Altitude
0~5000
M
Altitude Over 2000 meters, 1.5% derating for every 100 meters increase
Waterproof Level
IP67
Cooling method
Air convection
Temperature Coefficient
0.03%/℃ (0-60℃ )
Vibration
10-500Hz, 5G 12min./1cycle, period for 72 min, each along X.Y. Z axes
Safety Standards and EMC
Safety standard
UL8750, IEC/EN61347-1,EN61347-2-13,EN62368, GB19510.1,GB19510.14, IP67 Approved
Withstand voltage
I/P-O/P
3000Vac 10mA (Max)
I/P-FG
1500Vac 10mA (Max)
O/P-FG
500Vac 10mA (Max)
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Leakage Current
<0.75mA
240Vac/60Hz
Conducted
EN55015(CISPR15), GB17743
Radiated
EN55015(CISPR15), GB17743
Harmonic Current
EN61000-3-2 , Class C @load≥50%
ESD
EN61000-4-2, 8KV air ; Level 2, 4KV contact
Radiated
EN61000-4-3
EFT/Burst
EN61000-4-4
Surge
EN61000-4-5,4KV/Line-Line 6KV/Line-Earth
Conducted
EN61000-4-6
EN61547, Electromagnetic Immunity Requirements applies to lighting Equipment
MTBF
200Khours, MIL-HDBK-217F (25℃)
Dimension
115(L)*64 (W)*37(H)
Packing
0.41Kg;24pcs/ 10.5Kg/0.026CBM
Other Output Options Available:
Model NO
Input voltage
Output Voltage
Output Current
Output Power
Efficiency
APMS-60-24
176-305VAC
24VDC
0-2.5A
60W
87.5%
APMS-60-30
176-305VAC
30VDC
0-2.0A
60W
87.5%
APMS-60-36
176-305VAC
36VDC
0-1.66A
60W
88%
APMS-60-48
176-305VAC
48VDC
0-1.25A
60W
89%
APMS-60-54
176-305VAC
54VDC
0-1.1A
60W
89%
Datasheet Download
Contact: Jessica
Phone: 18625298070
Tel: 0519-69882666
Email: info@amcflex.com