Product Features:
1. 176-305VAC wide input voltage range
2. Constant Voltage Drive Mode
3. Built in active PF function, PF>0,95
4. High working efficiency up to 90%
5. THD<15%, Flicker-Free Design
6. IP67 waterproof level with fine aluminum housing, suitable for outdoor applications
7. Class 2 Power unit
8. 4KV + 6KV Surge protection, more safety
9. 5 years warranty
Model |
APMS-75-54 |
Remarks |
||
Output |
Rated Output voltage |
54 |
VDC |
|
Rated Output Current |
1.38 |
A |
||
Rated Output Power |
75 |
W |
||
Efficiency |
≥90% |
200VAC input, Rated Load |
||
≥90% |
240VAC input, Rated Load |
|||
Line Regulation |
±0.5% |
|||
Load Regulation |
±1.5% |
|||
Voltage tolerance |
±3% |
|||
Ripple & Noise (max) |
≤2.4 |
Vp-p |
Measured at 20MHZ of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor |
|
Rise time |
≤60 |
mS |
25℃ , full load |
|
Power On Delay time |
≤2 |
S |
200-240VAC, full load |
|
Switch off Hold Up time |
/ |
ms |
Rated input voltage, rated load |
Input |
Rated Input voltage |
200-277 |
VAC |
|
Input voltage range |
176-305 |
VAC |
||
Input Frequency |
47-63(Typical 50/60) |
Hz |
||
Input Current Max |
0.55 |
A |
Vin=176Vac, Full Load |
|
Inrush Current |
≤20 |
A |
220Vac, full load, 25℃ |
|
Power Factor |
≥0.95 |
176~277Vac input, full load |
||
THD |
≤15 |
% |
Vin=176~277Vac, full load |
|
Protection |
Current Limiting |
110%-160% |
Hi-CCUP Mode, Auto-recovery after fault condition is removed |
|
Input undervoltage |
>80 |
V |
||
Short circuit |
Yes |
Hi-CCUP Mode, Auto-recovery after fault condition is removed |
||
Environment |
Operating Temperature range |
-40 to +80(Typical25) |
℃ |
Refer to Derating Curve |
Storage Temperature range |
-45 to +80(Typical25 |
℃ |
||
Humidity |
10~95 |
% |
NON-Condensing |
|
Altitude |
0~5000 |
M |
Altitude Over 2000 meters, 1.5% derating for every 100 meters increase |
|
Waterproof Level |
IP67 |
|||
Cooling method |
Air convection |
|||
Temperature Coefficient |
0.03%/℃ (0-60℃ ) |
|||
Vibration |
10-500Hz, 5G 12min./1cycle, period for 72 min, each along X.Y. Z axes |
|||
Safety Standards |
Safety standard |
UL8750, IEC/EN61347-1,EN61347-2-13,EN62368, GB19510.1,GB19510.14, IP67 Approved |
||
Withstand voltage |
I/P-O/P |
3000Vac 10mA (Max) |
||
I/P-FG |
1500Vac 10mA (Max) |
|||
O/P-FG |
500Vac 10mA (Max) |
|||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||
Leakage Current |
<0.75mA |
240Vac/60Hz |
EMI |
Conducted |
EN55015(CISPR15), GB17743 |
Radiated |
EN55015(CISPR15), GB17743 |
|
Harmonic Current |
EN61000-3-2 , Class C @load≥50% |
|
EMS |
ESD |
EN61000-4-2, 8KV air ; Level 2, 4KV contact |
Radiated |
EN61000-4-3 |
|
EFT/Burst |
EN61000-4-4 |
|
Surge |
EN61000-4-5,4KV/Line-Line 6KV/Line-Earth |
|
Conducted |
EN61000-4-6 |
|
EN61547, Electromagnetic Immunity Requirements applies to lighting Equipment |
||
Others |
MTBF |
>200Khours, MIL-HDBK-217F (25℃) |
Dimension |
115(L)*64 (W)*37(H) |
|
Packing |
0.41Kg;24pcs/ 10.5Kg/0.026CBM |
Other Output Options Available:
Model NO |
Input voltage |
Output Voltage |
Output Current |
Output Power |
Efficiency |
APMS-75-24 |
176-305VAC |
24VDC |
0-3.125A |
75W |
88% |
APMS-75-30 |
176-305VAC |
30VDC |
0-2.5A |
75W |
88% |
APMS-75-36 |
176-305VAC |
36VDC |
0-2.1A |
75.6W |
90% |
APMS-75-48 |
176-305VAC |
48VDC |
0-1.56A |
75W |
90% |
APMS-75-54 |
176-305VAC |
54VDC |
0-1.38A |
75W |
90% |
Contact: Jessica
Phone: 18625298070
Tel: 0519-69882666
Email: info@amcflex.com